Back to wood log boilers
stueckholz icon

Wood Log Boiler

Neo-HV
20–60 kW

Hargassner Wood Log Generation
Energy label: A+
(Neo-HV 50)
Hot anniversary campaign - save now!

  • Filling chamber size for 1/2 metre log
  • Sophisticated wood gasification technology
  • Automatic boiler cleaning system
  • Smart-Touch screen
  • Filling chamber lighting as standard

Increased ease of operation & maintenance

The perfect gasifier for your log heating system

Hargassner stands for pioneering spirit and a wide range of experience. An excellent design and the high quality construction provides best functionality and optimal performance, resulting in high customer satisfaction and a long boiler lifetime. All technical details of the Neo-HV are optimised for optimum ease of operation and maintenance. A separate premium package increases the Hargassner operating comfort to a maximum. An all-round perfect gasifier for your own log heating system.

The Neo-HV 20–60 log boiler is also available as a wood log pellet combi boiler.

40 Years anniversary campaign: Order now and benefit from hot savings!
  • Autom. heat exchanger cleaning as standard
  • Convenient adjustment through touch display, infinitely adjustable
  • Unique automatic ceramic ignition (opt.)
  • Efficient auger turbulators for optimum heat exchange with longitudinal guide
  • Reinforced, conical filling chamber panels
  • New, optimised combustion technology
  • Full refractory-lined combustion chamber
  • Lambda sensor with autom. fuel-quality detection
  • Speed controlled EC exhaust fan
  • Large filling door 346 x 382 mm
  • Log-filling volume 166 l (Neo-HV 20-30) or 222 l (Neo-HV 40-60)
  • Filling depth 600 mm
  • Overhead smoulder gas slot
  • Highly-efficient insulation
  • Standard door hinge left (right possible on request)
  • Fully cased and wired - easy installation
  • Energy efficiency class A+
  • 5-year warranty acc. warranty card
  • Particle separator optional

Our boilers in detail

Specifics
of Neo-HV 20–60 kW

INNOVATIVE TECHNOLOGY IN REAL 3D VISUALISATION

Optimised for comfort: Discover the Neo-HV 20–60 by rotating, tilting or zooming in all directions as desired. You can also experience this solution for homes to agriculture here in 3D visualisation – now even in your boiler room. To do this, simply click on the AR button and place the wood log boiler using your mobile phone or tablet. Rotate and scale to get an accurate picture of how the Neo-HV 20–60 can be perfectly integrated into your room situation.

All technical details and important components can be found in the following sectional drawing.

Open 3D model in a new window
  1. Large filling door
  2. Large filling chamber for ½ m logs (up to 60 cm)
  3. Combustion chamber lining – prevents tar formation
  4. Heat-up door with automatic ignition (optional)
  5. Primary air motor
  6. Secondary air motor
  7. High-quality, massive refractory-lined combustion chamber
  8. High-temperature burnout zone
  9. Ash separation zone
  10. Lambda sensor
  11. Turbulators
  12. Heat exchanger
  13. Automatic boiler cleaning system
  14. Exhaust fan
  15. Top smoulder gas vent
  16. Optional back-end protection
  17. Cooling coil for thermal safety circuit
  18. Cleaning door
  19. Ash pan
  20. Filling chamber lighting as standard
View 3D model View cross section

Technical
details

Nominal capacity (NC)
Fuel heat output
Minimum capacity
Electric capacity
NCV efficiency at nominal output
NCV efficiency at 30 % nominal output
GCV efficiency at nominal output
GCV at 30 % nominal output
Seasonal energy efficiency ETAs
Boiler temperature range
Measures (w x h x d)
Weight
Filling volume
Space requirement
Flue pipe diameter
Ash box volume
Water content
Flow/Return
Energy label
Unit
kW
kW
kW
kW
%
%
%
%
%
°C
mm
kg
l
mm
l
l
"
    Neo-HV 20
    Nominal capacity (NC) 25,4 kW
    Fuel heat output 27,1 kW
    Minimum capacity 12,7 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,7 %
    NCV efficiency at 30 % nominal output (np) 92,8 %
    GCV efficiency at nominal output 84,1 %
    GCV efficiency at 30 % nominal output 83,5 %
    Seasonal energy efficiency ETAs 80 %
    Boiler temperature range 78 °C
    Measures (w x h x d) 660 x 1665 x 1310 mm
    Weight 700 kg
    Filling volume 166 l
    Space requirement 0,79
    Flue pipe diameter 150 mm
    Ash box volume - l
    Water content 137 l
    Flow/Return 6/4 (1) "
    Boiler label A+
    Neo-HV 30
    Nominal capacity (NC) 30 kW
    Fuel heat output 32,6 kW
    Minimum capacity 15 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 92 %
    NCV efficiency at 30 % nominal output (np) 92,8 %
    GCV efficiency at nominal output 85,9 %
    GCV efficiency at 30 % nominal output 83,6 %
    Seasonal energy efficiency ETAs 82 %
    Boiler temperature range 78 °C
    Measures (w x h x d) 660 x 1665 x 1310 mm
    Weight 700 kg
    Filling volume 166 l
    Space requirement 0,79
    Flue pipe diameter 150 mm
    Ash box volume - l
    Water content 137 l
    Flow/Return 6/4 (1) "
    Boiler label A+
    Neo-HV 40
    Nominal capacity (NC) 40 kW
    Fuel heat output 43,3 kW
    Minimum capacity 20 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 92,3 %
    NCV efficiency at 30 % nominal output (np) 93,7 %
    GCV efficiency at nominal output 85,1 %
    GCV efficiency at 30 % nominal output 84,4 %
    Seasonal energy efficiency ETAs 81 %
    Boiler temperature range 78 °C
    Measures (w x h x d) 740 x 1730 x 1370 mm
    Weight 810 kg
    Filling volume 222 l
    Space requirement 0,88
    Flue pipe diameter 150 mm
    Ash box volume - l
    Water content 166 l
    Flow/Return 6/4 (1) "
    Boiler label A+
    Neo-HV 50
    Nominal capacity (NC) 49 kW
    Fuel heat output 53 kW
    Minimum capacity 24,5 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 92,5 %
    NCV efficiency at 30 % nominal output (np) 94,4 %
    GCV efficiency at nominal output 84,4 %
    GCV efficiency at 30 % nominal output 85,2 %
    Seasonal energy efficiency ETAs 82 %
    Boiler temperature range 78 °C
    Measures (w x h x d) 740 x 1730 x 1370 mm
    Weight 810 kg
    Filling volume 222 l
    Space requirement 0,88
    Flue pipe diameter 150 mm
    Ash box volume - l
    Water content 166 l
    Flow/Return 6/4 (1) "
    Boiler label A+
    Neo-HV 60
    Nominal capacity (NC) 60 kW
    Fuel heat output 64,7 kW
    Minimum capacity 30 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 92,8 %
    NCV efficiency at 30 % nominal output (np) 95,4 %
    GCV efficiency at nominal output 83,4 %
    GCV efficiency at 30 % nominal output 86,1 %
    Seasonal energy efficiency ETAs 82 %
    Boiler temperature range 78 °C
    Measures (w x h x d) 740 x 1730 x 1370 mm
    Weight 810 kg
    Filling volume 222 l
    Space requirement 0,88
    Flue pipe diameter 150 mm
    Ash box volume - l
    Water content 166 l
    Flow/Return 6/4 (1) "
    Boiler label A+

    NCV = Net Calorific Value | GCV = Gross Calorific Value
    max. operation temperature 95 °C | max. operating pressure 3 bar | electrical supply 230 V AC, 50 Hz, 13 A fuse protection

    The right boiler for every power requirement.

    Your new heating system
    in just a few steps

    More about Hargassner

    01

    Contact us

    Contact us for get some more
    information and make an appointment!

    02

    Request

    Our team looks forward to
    hearing from you and providing
    you with professional advice.

    03

    Appoint­ment

    We will inform you in detail
    about our heating systems and the
    corresponding heating supplies
    for your biomass heating system.

    04

    Offer

    We create an energy- and
    cost-efficient offer that
    is tailored to your needs.

    In your region

    Find a
    contact person

    nearby

    Find a contact person